SEUs indiced by thermal to high-energy neutrons in SRAMs /
We report on experimetnal SEU studies using thermal and high-energy neutrons, conducted at the TRIUNF facility, Vancouver. Different SRAM samples were used an many samples showed to be highly susceptible to thermal neutrons. Morover, a considerable part of the total SEU-rate, at high altitudes as we...
Guardado en:
Publicado en: | IEEE Transactions on Nuclear Science |
---|---|
Autor principal: | |
Otros Autores: | , |
Formato: | Sin ejemplares |
Lenguaje: | |
Colección: | IEEE Transactions on Nuclear Science vol. 53, no. 6, pt. 2 (Dec. 2006), p. 3798-3802. |
Materias: | |
Publicación relacionada: | Contenido en:
IEEE Transactions on Nuclear Science |
Sumario: | We report on experimetnal SEU studies using thermal and high-energy neutrons, conducted at the TRIUNF facility, Vancouver. Different SRAM samples were used an many samples showed to be highly susceptible to thermal neutrons. Morover, a considerable part of the total SEU-rate, at high altitudes as well as down at sea level, may be attributed to thermal neutrons for RAM based devices. |
---|---|
Notas: | Trabajo presentado en: 2005 Radiation and Its Effects on Components and Systems (RADECS) Conferences, Palais des Congrès, Cap d' Agde, France, September 19-23, 2005. |
Descripción Física: | 4 p. : il. ; 28 cm. |
Bibliografía: | Bibliografía: p. [4]. |